 PD -2.472 rev. B 01/99
HFA80NC40CSL
HEXFRED
Features
* Reduced RFI and EMI * Reduced Snubbing * Extensive Characterization of Recovery Parameters
TM
Ultrafast, Soft Recovery Diode
VR = 400V VF(typ.) = 1V IF(AV) = 80A Qrr (typ.) = 200nC IRRM(typ.) = 6A trr(typ.) = 30ns di(rec)M/dt (typ.) = 190A/s
Description
HEXFRED diodes are optimized to reduce losses and EMI/RFI in high frequency power conditioning systems. An extensive characterization of the recovery behavior for different values of current, temperature and di/dt simplifies the calculations of losses in the operating conditions. The softness of the recovery eliminates the need for a snubber in most applications. These devices are ideally suited for power converters, motors drives and other applications where switching losses are significant portion of the total losses.
TM
SLD-61-8
Absolute Maximum Ratings (per Leg)
Parameter
VR IF @ TC = 25C IF @ TC = 100C IFSM EAS PD @ TC = 25C PD @ TC = 100C TJ TSTG Cathode-to-Anode Voltage Continuous Forward Current Continuous Forward Current Single Pulse Forward Current Non-Repetitive Avalanche Energy Maximum Power Dissipation Maximum Power Dissipation Operating Junction and Storage Temperature Range Soldering Temperature, for 10 sec.
Max.
400 85 42 300 1.4 150 59 -55 to +150 300 (0.063 in. (1.6mm) from case)
Units
V A mJ W C
Thermal - Mechanical Characteristics
Parameter
RthJC Wt Junction-to-Case, Single Leg Conducting Junction-to-Case, Both Legs Conducting Weight
Min.
---- ---- ----
Typ.
---- ---- 4.3 (0.15)
Max.
0.85 0.42 ----
Units
C/W K/W g (oz)
Note: Limited by junction temperature L = 100H, duty cycle limited by max TJ 125C 1
HFA80NC40CSL
PD-2.472 rev. B 01/99
Electrical Characteristics (per Leg) @ TJ = 25C (unless otherwise specified)
Parameter
V BR V FM Cathode Anode Breakdown Voltage Max Forward Voltage
Min. Typ. Max. Units
400 --- --- 1.1 --- 1.3 --- 1.0 --- 0.50 --- 0.75 --- 90 --- 5.5 --- 1.3 1.5 1.2 3.0 4.0 125 --- V V A mA pF nH
Test Conditions
IR = 100A IF = 40A IF = 80A See Fig. 1 IF = 40A, TJ = 125C VR = VR Rated See Fig. 2 TJ = 125C, VR = 320V VR = 200V See Fig. 3 Lead to lead 5mm from package body
IRM CT LS
Max Reverse Leakage Current Junction Capacitance Series Inductance
Dynamic Recovery Characteristics (per Leg) @ TJ = 25C (unless otherwise specified)
Parameter
t rr trr1 trr2 IRRM1 IRRM2 Qrr1 Qrr2 di(rec)M/dt1 di(rec)M/dt2 Reverse Recovery Time
Min. Typ. Max. Units
--- --- --- --- --- --- --- --- --- 30 --- 67 100 ns 110 170 6.0 11 A 9.0 16 200 540 nC 500 1300 240 --- A/s 190 ---
Test Conditions
IF = 1.0A, dif/dt = 200A/s, VR = 30V TJ = 25C See Fig. TJ = 125C IF = 40A 5 TJ = 25C See Fig. TJ = 125C VR = 200V 6 TJ = 25C See Fig. TJ = 125C 7 dif/dt = 200A/s TJ = 25C See Fig. TJ = 125C 8
Peak Recovery Current Reverse Recovery Charge Peak Rate of Fall of Recovery Current During tb
FOOT PRINT
Outline D 61- 8-SL
Dimensions in millimeters and (inches)
2
HFA80NC40CSL
PD-2.472 rev. B 01/99
1000 10000
R e ve rse C u rre n t - I R ( A )
TJ = 150C
1000
In sta n ta n e o u s F o rw a rd C u rre n t - I F (A )
100
TJ = 125C
10
100
1
TJ = 25C
0.1 0 100 200 300 400
TJ = 150C TJ = 125C TJ = 25C
10
R e ve rse V o lta g e - V R (V )
Fig. 2 - Typical Reverse Current vs. Reverse Voltage, (per Leg)
Ju nction C a pa cita nce - C T (p F )
1000
A
TJ = 2 5 C
100
1 0.4 0.8 1.2 1.6 2.0
F o rw a rd V o lta g e D ro p - V FM (V )
Fig. 1 - Maximum Forward Voltage Drop vs. Instantaneous Forward Current, (per Leg)
1
10 1 10 100 1000
R e v e rs e V o lta g e - VR (V )
Fig. 3 - Typical Junction Capacitance vs. Reverse Voltage, (per Leg)
T h e rm a l Im p e d a n ce - Z thJC (K /W )
D = 0.50
D = 0.33 D = 0.25 D = 0.1 7 D = 0.08
0.1
PD M
t
S ingle P ulse (The rm a l Resis ta nce)
1
t2 N o te s: 1 . D u ty fa c to r D = t 1 /t 2
2 . P e a k TJ = P D M x Z th JC + TC
0.01 0.0001 0.001 0.01 0.1 1 10 100
t 1 , R e cta n g u la r P u lse D u ra tio n (S e c o n d s )
Fig. 4 - Maximum Thermal Impedance Zthjc Characteristics, (per Leg)
3
HFA80NC40CSL
PD-2.472 rev. B 01/99
160 100
140
VR = 2 0 0 V T J = 1 2 5 C T J = 2 5 C
VR = 2 0 0 V T J = 1 2 5 C T J = 2 5 C
120
100
I IR R M - (A )
t rr - (n s)
I F = 100A
10
I F = 100A
80
I F = 40A I F = 20A
I F = 40A
I F = 20 A
60
40 100
d i f /dt - (A / s)
1000
1 100
1000
d i f /d t - (A / s)
Fig. 5 - Typical Reverse Recovery vs. dif/dt, (per Leg)
2500
Fig. 6 - Typical Recovery Current vs. dif/dt, (per Leg)
10000
VR = 2 0 0 V T J = 1 2 5 C T J = 2 5 C
2000
VR = 2 0 0 V T J = 1 2 5 C T J = 2 5 C
1500
I F = 100A I F = 40A
1000
d i(re c)M /d t - (A / s)
Q R R - (n C )
I F = 20A
1000
I F = 40A
I F = 20A
I F = 100A
500
0 100
d i f /d t - (A / s)
1000
100 100
1000
d i f /d t - (A / s)
Fig. 7 - Typical Stored Charge vs. dif/dt, (per Leg)
4
Fig. 8 - Typical di(rec)M/dt vs. dif/dt, (per Leg)
HFA80NC40CSL
PD-2.472 rev. B 01/99
3
IF
t rr ta tb
4
R E V E R S E R E C O V E R Y C IR C U IT
V R = 2 00 V
0 Q rr
2
I RRM
0.5 I R R M di(re c)M /dt
5
0.01 L = 70H D .U .T. D G IR F P 2 50 S
1
0.75 I R R M di f /d t
4. Qrr - Area under curve defined by trr and IRRM trr X IRRM Qrr = 2 5. di(rec)M/dt - Peak rate of change of current during tb portion of trr
d if/d t A D JU S T
1. dif/dt - Rate of change of current through zero crossing 2. IRRM - Peak reverse recovery current 3. trr - Reverse recovery time measured from zero crossing point of negative going IF to point where a line passing through 0.75 IRRM and 0.50 IRRM extrapolated to zero current
Fig. 9 - Reverse Recovery Parameter Test Circuit
L = 1 00 H H IG H -S P E E D S W IT C H R g = 2 5 o hm CURRENT M O N IT O R F R E E -W H E E L D IO D E + V d = 5 0V
Fig. 10 - Reverse Recovery Waveform and Definitions
I L(PK )
DUT
DECAY T IM E V (AV A L) V R (R AT E D )
Fig. 11 - Avalanche Test Circuit and Waveforms
WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245 U.S.A. Tel: (310) 322 3331. Fax: (310) 322 3332. EUROPEAN HEADQUARTERS: Hurst Green, Oxted, Surrey RH8 9BB, U.K. Tel: ++ 44 1883 732020. Fax: ++ 44 1883 733408. IR CANADA: 15 Lincoln Court, Brampton, Markham, Ontario L6T3Z2. Tel: (905) 453 2200. Fax: (905) 475 8801. IR GERMANY: Saalburgstrasse 157, 61350 Bad Homburg. Tel: ++ 49 6172 96590. Fax: ++ 49 6172 965933. IR ITALY: Via Liguria 49, 10071 Borgaro, Torino. Tel: ++ 39 11 4510111. Fax: ++ 39 11 4510220. IR FAR EAST: K&H Bldg., 2F, 30-4 Nishi-Ikebukuro 3-Chome, Toshima-Ku, Tokyo, Japan 171. Tel: 81 3 3983 0086. IR SOUTHEAST ASIA: 1 Kim Seng Promenade, Great World City West Tower,13-11, Singapore 237994. Tel: ++ 65 838 4630. IR TAIWAN: 16 Fl. Suite D.207, Sec. 2, Tun Haw South Road, Taipei, 10673, Taiwan. Tel: 886 2 2377 9936.
ht:/w.r.o tp/wwifcm
FxO-ead +4 18 732 a-nDmn: 4 83 340
D t a d s e i i a i n s b e t t c a g w th u n t c . aa n pcfctos ujc o hne i ot oie
5


▲Up To Search▲   

 
Price & Availability of HFA80NC40CSL

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X